"camera lens test chart"
拡張されるカスタマイズ可能な視力の図表のSineImage ISO 12233/2014 E-SFRの試験標板
SineImage ISO 12233:2014 E-SFR test charts-Extended Model ISO 12233:2014 Edge SFR Type Reflective Size 1X,2X,4X Ratio 4:3/16:9 Chart Size Standard Enhanced Extended 1x 200 mm × 305 mm ER-SD-100A 200 mm × 305 mm ER-ST-100A 200 mm × 365 mm ER-EX-100A 2x 400 mm × 610 mm ER-SD-200A 400 mm × 610 mm ER-ST-200A 400 mm × 730 mm ER-EX-200A 4x 800 mm × 1220 mm ER-SD-400A 800 mm × 1220 mm ER-ST-400A 800 mm × 1460 mm ER-EX-400A 8x 1600 mm x 2440 mm ER-SD-800A 1600 mm x 2440 mm ER-ST-800A
色収差/SMIA TVのゆがみをテストするドット・パターンの決断の試験標板
Dot Pattern Test Chart Dot Pattern Test Chart is for testing chromatic aberration and SMIA TV Distortion. The medium chart is sized 24" x 36" The XL chart is sized 44" x 66" For the medium sized chart, the dot size is 0.498" in diameter for the large dots (15 high), and 0.299" in diameter for the smaller dots (25 high) For the XL sized chart, the dot size is 0.924" for the large dots (15 high) and 0.555" in diameter for the smaller dots (25 high) SKU Size
8k UHD TV2の決断の試験標板200-4000 Cph 16/9の透明な18%伝達
8K (UHD TV2) RESOLUTION TEST CHART 200-4000 CPH 16:9 TRANSPARENT The TE278 is designed to measure and describe the frequency response of an electronic 8K (UHD TV2) camera. The test chart consists of 50 multiburst fields, which are distributed over 16:9 picture area. The fields are arranged in horizontal and vertical direction to measure resolution in both directions. All fields are labeled with the resolution in cycles per picture height. A cycle consists of one black and one
ISO 12233の標準レンズの決断の試験標板、反射カメラの試験標板
4:3 and 3:2 CERTIFICATE LENS RESOLUTION TEST CHART REFLECTIVE CAMERA TEST CHART The test chart TE268 is designed for resolution and sharpness measurements. The chart can be analyzed automatically with the iQ-Analyzer. Five different structures in the chart allow a numerical and visual analysis: • 25 sinusoidal Siemens stars are placed at the chart. The stars have a gray value which changes sinusoidal when walking on a circle around the center of the star. • Each star is
デジタル カメラの無彩色スケールOECFの測定の試験標板TE269 OECF36 RoHSの承認
digital camera grey scale OECF measurement test chart TE269 OECF36 1.000.000:1 OECF MEASUREMENT The opto electronic conversion function (described in ISO 14524) is one the most important characteristics of a digital camera. It describes how the camera transforms luminance values of an object or illuminance values on the sensor plane into digital code values in the digital image. The OECF is typically measured from a grey scale. Depending on the type of camera different
Transmissive証明されたカメラの試験標板の調整された正弦ジーメンス スター
TRANSMISSIVE CERTIFICATE MODULATED SINUSOIDAL SIEMENS STAR Camera Test Chart The chart TE253 D35 9x contains nine radially sine modulated Siemens stars, slanted edges and white noise patches. The center of each star shows a registration marker. Each star is surrounded by 16 gray patches, used for linearisation. The corners are showing a bigger black square with a small white square in it. The chart is available with Siemens stars with 144 and 72 periods. The two sets of
14524灰色レベルのカメラの試験標板Oecf20 10.000/1 X版Transmissive ISO
Camera Test Chart OECF20 10.000:1 (X-VERSION) TRANSMISSIVE ISO 14524 gray levels chart Step Measured Density Reference Density Deviation 1 0.03 2 0.10 3 0.17 4 0.24 5 0.32 6 0.41 7 0.50 8 0.59 9 0.70 10 0.81 11 0.94 12 1.08 13 1.23 14 1.41 15 1.61 16 1.85 17 2.15 18 2.53 19 3.08 20 4.03 Background 1.38 The specification of TE270X D is derived from ISO 14524. Standard versions of OECF charts use a screening to form the gray levels. This may lead to increased noise levels or
正弦のイメージのマクロ レンズのマクロ カメラの試験標板の決断/ゆがみの分析
Silk MACRO TEST CHART analysis of resolution and distortion of macro lenses The TE274 Macro Test Chart is designed for the analysis of resolution and distortion of macro lenses attached to SLR and system cameras and compact cameras in macro mode. The TE274 consists of two parts: • Slanted edges for resolution measurement The chart contains 15 slanted edge structures, each with two vertical and two horizontal edges and a focussing aid in the center. The slanted edge
標準的な版決断の試験標板のSineImage ISO 12233/2014 E-SFRのタイプ
SineImage ISO 12233:2014 E-SFR test charts -Standard Version This sfr test chart, which has a 3:2 aspect ratio, is a "no-frills" implementation of the standard. For most work we recommend the Enhanced or Extended charts, which have additional edges for measuring performance near the image boundaries, as well as hyperbolic wedges and color patches (where the technology allows). These chartsmaintain full compliance with the standard. The Imatest Standard ISO 12233:2014 E-SFR
36のパッチの決断の試験標板低雑音50db 100db 150dbは高いダイナミック レンジを図表にします
36-Patch low-noise 50db, 100db and 150db charts High Dynamic Range (HDR) 36 Level Test Card Transparent Test Chart for MTF Model YE0269 Type Transparent Format Custom Designs Ratio 16:9 This Sineimage 36-Patch Dynamic Range Test Chart YE0269 Transparent has 36 low-noise density patches with density steps of approximately 0.1, for a density range of at least 3.2 (density from base to base + 3.1 minimum). A nearly circular patch arrangement ensures that vignetting has minimal
ISO12233決断の試験標板の調節可能なIllumiation色の臨時雇用者箱の標準光源
Camera Testing Standard Light Source T120-4 Photography fill light box from Silk T8B-X Adjustable Illumination / Color Temperature Fill Light Box is produced independently by Beijing Silk technology co.ltd and it is special design for camera test use. This product uses LED light source with the performance of high power, high illumination, no flicker, long life, stable color temperature and it provides professional lighting environment for camera lens evaluation system,
無彩色スケールの決断の試験標板20水平なテスト カードYE0259透明なSilk
Silk Grey Scale 20 Level Test Card Grayscale Chart YE0259 Transparent Certificates: ISO9001:2008; CE; FCC; ROHS; TUV. SineImage 20 steps grayscale chart YE0259 Brand Silk Model YE0259 Size 280*157.5mm (Customized) Material Film Ratio 16:9 Type Transparent The YE0259 is designed to check the dynamic range of broadcasting cameras on a waveform monitor. Two 20-step graduated counter current gray scale are arranged on a gray background (D = 1.35),the gray scale is graded in